Scan Part Number

Tap the focus box or CAPTURE to scan the part number.

Pinch screen or tap 1.4x button to zoom.

Recognizing Part Number...

PK200F160 SanRex 1600 V 200 A Thyristor Module

  • PK200F160
  • PK200F160 SanRex thyristor module for SVC and thyristor-switched capacitor compatibility checks. Review 1600 V, 200 A ratings for repairs.

    · Categories: Thyristor Module
    · Manufacturer: SanRex
    · Price:
    Price Range: US$ 50 - US$ 200 (Estimated)
    Submit RFQ to Get Price
    · Date Code: Please Verify on Quote
    . Available Qty: 232
    MOQ: 1 PC
    Express Shipping
    90-Day Warranty
    1-2 Days Lead Time
    100% Tested
    Whatsapp: 0086 189 2465 1869

    Content last revised on November 16, 2026

    PK200F160 Maintenance Checks and Specifications

    • Isolate the equipment, verify stored energy is discharged, and disconnect parallel paths before checking main-terminal resistance and gate-to-cathode continuity.
    • Match the module circuit symbol and terminal markings to the equipment schematic before reconnecting power conductors or firing leads.
    • Inspect the heatsink contact surface, thermal interface condition, mounting hardware, and airflow passages before energization.
    • Check gate-driver isolation and look for moisture or condensation around terminal barriers before commissioning.

    The PK200F160 is a SanRex Thyristor / Diode Module in an Isolated Power Module package. Its maintenance assessment should keep the semiconductor ratings, firing circuit, and cooling assembly together: a satisfactory cold resistance check does not establish correct operation under load.

    Official Specification Value
    Manufacturer SanRex
    Part Number PK200F160
    Product Category Thyristor Module
    Repetitive Peak Reverse Voltage (VRRM) 1600.0 V
    Average On-State Current (IT(AV)) 200.0 A under the specified datasheet conditions
    Package Isolated Power Module
    Configuration / Topology Thyristor / Diode Module

    Consult the manufacturer datasheet for rating conditions, terminal diagrams, mounting torque, gate limits, surge ratings, and thermal characteristics. SanRex Sansha Electric Power Semiconductor Modules provides the manufacturer reference point for matching device documentation.

    Field Diagnostics & Commissioning: High-di/dt Gate Firing: Pulse-Train Timing in PK200F160 Topologies

    Measure firing current at the gate-to-cathode connection and correlate it with anode current during initial conduction. As a Design Consideration, a command pulse at the controller does not demonstrate adequate gate drive at the module: cable impedance, connection resistance, and driver loading can change the delivered waveform.

    Check the pulse leading edge, duration, and subsequent pulse train against the driver specification and semiconductor gate limits. Gate trigger current and voltage, IGT and VGT, describe triggering conditions rather than unrestricted drive settings. Strong initial drive can support conduction spreading, but excessive gate excitation can exceed gate power limits; the system designer should validate both conditions.

    Distinguish gate-pulse support from thyristor holding current. The gate waveform’s sustaining portion helps establish conduction, whereas holding current concerns the main anode path. Repeated firing pulses can accommodate changing conduction opportunities, but cannot guarantee continued conduction when anode current falls below the sustaining requirement.

    For cold screening, compare isolated main-terminal and gate-path readings with the circuit diagram and a known-good assembly under equivalent conditions. A meter reading alone cannot establish blocking capability at rated voltage. During replacement assessment, compare PK200FG120 documentation for circuit arrangement, blocking ratings, gate requirements, and mechanical fit; the related designation does not establish drop-in compatibility.

    PK200F160 Circuit Protection & Reliability: Calibrating Power Factor Degradation and Harmonic Mitigation

    Record line current and delivered output while changing the firing command within the equipment’s permitted operating range. As a Design Consideration, conversion behavior depends on bridge arrangement, load continuity, and commutation conditions; a universal firing-angle transfer curve would misrepresent this thyristor/diode configuration.

    Separate displacement effects from waveform distortion when evaluating power factor. Delayed conduction changes current timing and shape, so output regulation alone does not establish acceptable upstream harmonic loading. Engineers evaluating a grid-tied static var compensator or thyristor-switched capacitor assembly should verify valve arrangement, blocking requirements, and switching duty before considering this module for that equipment.

    Coordinate semiconductor fuses using the device surge-current and I²t data alongside the fuse manufacturer’s total clearing characteristics at the actual prospective fault current. Include operating temperature and recovery conditions in that assessment. Fuse coordination supports fault limitation; it is not an unconditional guarantee against package rupture during a short circuit.

    The Power, Safety, Efficiency Technical Reference offers broader power-conversion context, but IGBT switching guidance should not be transferred directly to thyristor firing control. Maintenance Note: Trend terminal temperature rise and inspect cooling passages during scheduled maintenance, using approved tightening procedures rather than tightening connections while energized.

    Transient Dynamics & Electrical Design: Minimizing Commutation Turn-Off Voltage Spikes on PK200F160

    Capture module terminal voltage and commutating current together to distinguish recovery-related overshoot from measurement-loop ringing. As a Design Consideration, diode reverse-recovery current and duration depend on operating conditions; neither soft-recovery behavior nor specific recovery values should be inferred from the product designation.

    Keep commutation paths compact and evaluate busbar geometry against the actual current loop. Coordinate any MOV and snubber network with repetitive voltage stress, absorbed energy, and component heating, then verify terminal waveforms over the intended operating envelope. A thyristor normally turns off through current commutation, not an IGBT-style gate turn-off command.

    For measurement practice and recovery mechanisms, IEEE Transactions on Power Electronics provides relevant technical literature. During thermal servicing, inspect interface deterioration and heatsink flatness, apply the approved assembly procedure, and allow condensation to clear before energization; maintenance intervals should follow observed contamination and temperature trends.