Scan Part Number

Tap the focus box or CAPTURE to scan the part number.

Pinch screen or tap 1.4x button to zoom.

Recognizing Part Number...

TZ425N16KOF Infineon 1600V 425A Thyristor Module

  • TZ425N16KOF
  • Evaluate TZ425N16KOF Infineon 1600V 425A thyristor module compatibility for high-voltage three-phase motor soft starter repairs.

    · Categories: Thyristor Module
    · Manufacturer: Infineon
    · Price:
    Price Range: US$ 50 - US$ 200 (Estimated)
    Submit RFQ to Get Price
    · Date Code: Please Verify on Quote
    . Available Qty: 293
    MOQ: 1 PC
    Express Shipping
    90-Day Warranty
    1-2 Days Lead Time
    100% Tested
    Whatsapp: 0086 189 2465 1869

    Content last revised on November 14, 2026

    Field Diagnostics & Commissioning: High-di/dt Gate Firing: Pulse-Train Timing in TZ425N16KOF Topologies

    Isolate the power circuit, verify that stored energy has discharged, and disconnect parallel paths before checking the TZ425N16KOF main terminals with a meter. Compare readings with the circuit diagram and an equivalent healthy branch; an in-circuit resistance reading alone cannot establish thyristor condition. Inspect terminal seating, gate connections, and the heatsink contact surface before preparing an energized test.

    The Infineon TZ425N16KOF is a Thyristor Module with a specified Thyristor / Diode Module configuration. Its repair assessment centers on firing behavior, semiconductor fuse coordination, and heat removal—not IGBT switching assumptions. The following specification baseline identifies the component; operating conditions remain essential when applying its ratings.

    Capture gate current relative to its cathode return while observing main-terminal voltage and load-current establishment. Design Consideration: a controller firing command does not prove that sufficient gate current reaches the thyristor. Connector resistance, driver loading, and return-path coupling can alter the delivered pulse, so inspect the waveform at the module connection rather than only at the control board.

    The product specification baseline is Manufacturer: Infineon; Part Number: TZ425N16KOF; Repetitive Peak Reverse Voltage (VRRM): 1600.0 V; Average On-State Current (IT(AV)): 425.0 A under the datasheet-specified conditions; Package: PowerBLOCK Module; and Configuration / Topology: Thyristor / Diode Module. VRRM is a reverse-blocking rating, not an equipment supply-voltage designation.

    Design Consideration: distinguish gate triggering current from main-circuit latching and holding currents. A sustained gate-pulse portion can support turn-on while load current builds, but it is not the thyristor holding-current rating. Pulse-train operation should maintain suitable triggering opportunities through the intended conduction interval without exceeding permitted gate loading. Evaluate the leading edge and subsequent pulses against the device gate characteristics and controller specification, rather than imposing a generic gate-current rise-time target.

    Repeated firing interruptions warrant checking phase synchronization, pulse delivery, and load-current continuity together. Uneven turn-on can concentrate initial conduction, but a distorted waveform does not independently establish internal damage. Infineon’s EiceDRIVER gate-driver portfolio provides broader driver context; it does not establish compatibility with this thyristor’s triggering requirements.

    Preventing Spurious Faults: Short-Circuit Withstand Limits: Coordination Guidelines for TZ425N16KOF

    Compare the semiconductor fuse’s total clearing I²t with the module’s applicable withstand data under matching fault conditions. Design Consideration: fuse current rating alone cannot establish protection coordination. Prospective fault current, recovery voltage, initial junction temperature, and clearing duration influence whether the protection arrangement limits semiconductor stress adequately.

    Build the coordination record from the fuse manufacturer’s clearing curves and the module’s surge-current documentation. Separate pre-arcing energy from total clearing energy, and distinguish a nonrepetitive ITSM event from permissible repeated overloads. After a surge, restart timing should follow the calculated thermal recovery and equipment protection strategy; a successful continuity check does not establish restored thermal margin. No fuse selection by itself guarantees damage-free operation during every short circuit.

    For replacement assessment, compare terminal arrangement and electrical function before comparing headline current. The T640N14TOF can enter a documented candidate review, but it is not established here as a direct replacement. The comparison below separates the TZ425N16KOF baseline from the checks needed before approving another part.

    Selection checkpoint TZ425N16KOF T640N14TOF candidate review
    Repetitive peak reverse voltage 1600.0 V Consult datasheet
    Average on-state current 425.0 A under the datasheet-specified conditions Consult datasheet and rating conditions
    Configuration Thyristor / Diode Module Verify circuit symbol and terminal mapping
    Package PowerBLOCK Module Verify drawing, footprint, and connections
    Protection compatibility Check ITSM and I²t conditions Reassess fuse and triggering coordination

    ⚠️ Field Alert: Use the specified mounting and terminal torques for the actual module hardware, and restore a clean, uniform thermal interface before energizing.

    TZ425N16KOF Thermal-Electrical Optimization: Harmonic Current Injection and Line Filter Practical Tuning

    Record current waveform, conduction interval, and case-temperature trend across the intended operating sequence before changing filter components. Design Consideration: phase-angle control changes waveform shape as well as delivered power, so average current alone cannot describe conduction losses, harmonic loading, or power factor. Evaluate these effects using the actual circuit topology and load.

    When assessing compatibility with a high-voltage three-phase motor solid-state soft starter, verify the complete power-stage arrangement and equipment voltage requirements. The module’s reverse-blocking rating does not establish suitability for that equipment class. Inspect neighboring supply-stage components, including devices considered alongside the DDB6U134N16, through the system schematic rather than assuming interchangeable functions.

    Engineering Recommendation: evaluate pulse heating with the applicable transient thermal impedance and loss data, including accumulated heating during repeated starts. Keep main-current loops compact to limit inductive transients, and assess RC snubber damping against measured voltage rise and commutation behavior. Component values and layout acceptance should come from system testing, including checks for filter resonance and added snubber heating.

    The AI, Energy, and IGBT Technical Reference offers broader power-stage context, while Infineon’s EconoDUAL 3 information concerns a different module family. Neither supplies TZ425N16KOF limits. Complete recommissioning by checking phase-current consistency, terminal heating, and protection operation against the equipment’s approved acceptance criteria.