Scan Part Number

Tap the focus box or CAPTURE to scan the part number.

Pinch screen or tap 1.4x button to zoom.

Recognizing Part Number...

LQ150P1JX01 Sharp 15.0-Inch 2496×1664 eDP LCD Display

  • LQ150P1JX01
  • Evaluate the Sharp LQ150P1JX01 LCD for substation SCADA console repairs: 15.0-inch, 2496×1664, four-lane eDP, with integration checks.

    · Categories: LCD Display
    · Manufacturer: Sharp
    · Price:
    Price Range: US$ 50 - US$ 200 (Estimated)
    Submit RFQ to Get Price
    · Date Code: Please Verify on Quote
    . Available Qty: 65
    MOQ: 1 PC
    Express Shipping
    90-Day Warranty
    1-2 Days Lead Time
    100% Tested
    Whatsapp: 0086 189 2465 1869

    Content last revised on November 2, 2026

    Sharp LQ150P1JX01 Specifications and Installation Checks

    • Disconnect display power before inspecting the LQ150P1JX01 connector, cable retention, and chassis bonding contacts.
    • Check that the host provides four-lane eDP and supports the panel’s 2496 × 1664 native resolution.
    • Compare the mounting cavity with the 323.32 × 231.59 × 2.4 mm outline, allowing for cable clearance and gasket compression.
    • Inspect the bezel seal, ventilation path, and enclosure for trapped moisture before applying power.

    The Sharp LQ150P1JX01 is a 15.0-inch oxide TFT-LCD with a normally black, transmissive display and edge-lit WLED backlighting. Its integration priorities are connector compatibility, mechanical support, and stable optical performance after installation. The specification card below separates supplied product values from installation details that require the panel drawing and electrical specification.

    Feature Product specification
    Display technology Oxide TFT-LCD; normally black; transmissive
    Diagonal size 15.0 inches
    Native resolution and density 2496(RGB) × 1664; 199 PPI
    Active area 317.117(W) × 211.411(H) mm
    Outline dimensions 323.32(W) × 231.59(H) × 2.4(D) mm
    Typical brightness 510 cd/m²
    Typical contrast ratio 1500:1
    Viewing angles 89°/89°/89°/89°, left/right/up/down, at CR ≥ 10
    Color support 16.7 million colors; 100% sRGB gamut
    Signal interface eDP; four lanes; 60-pin connector
    Backlight WLED; edge light type
    Supplied backlight life entry 12,000 hours; test conditions and endpoint: consult datasheet
    Electrical and installation limits Supply voltage, connector pinout, sequencing, temperature limits, and mounting tolerances: consult datasheet

    Radiated Emissions Assessment and Backplate Grounding

    Inspect the cable shield termination and backplate contact surfaces when image disturbance changes with nearby switching equipment. As a Design Consideration, route the eDP harness away from power conductors and maintain the enclosure’s intended shield continuity. Pixel jitter or horizontal bands can accompany interference, but connector intermittency, link configuration, and supply disturbance also deserve investigation.

    A circumferential shield connection can reduce a cable entry’s high-frequency impedance when the connector and enclosure support that construction. Backplate bonding, star connections, and distributed chassis contacts serve different frequency-dependent purposes; their arrangement should follow the enclosure design and measurement results. Common-mode suppression components require signal-integrity evaluation because an unsuitable part can also degrade the display link.

    CISPR Class A or Class B performance belongs to the assessed equipment configuration. This panel’s interface and optical specifications do not establish an emissions classification, and a grounding arrangement alone cannot establish compliance. Compare disturbance behavior during controlled equipment operation, then assess the completed assembly using the applicable product standard.

    For broader enclosure practices, Industrial Display & HMI Solutions provides related integration context. Cold operation also calls for checking the specified operating range: liquid-crystal transitions can slow as temperature falls. Any enclosure heating should be governed by the system’s environmental assessment, including condensation during temperature transitions.

    Luminance Assessment and Backlight Service Life

    Compare brightness at a repeatable backlight setting after the assembled display reaches thermal stability. The 510 cd/m² typical brightness and 1500:1 typical contrast ratio describe panel optical characteristics; installed performance also depends on cover glass, reflections, temperature, and viewing conditions.

    As a Design Consideration, examine temperature distribution around the illuminated edges and the backlight driver before adding thermal hardware. An enclosure heat spreader should transfer heat through approved contact regions without loading the thin display assembly. Localized heating can affect luminance uniformity and optical performance, but the internal optical material should not be assumed from the backlight type.

    The supplied 12,000-hour backlight life entry is not sufficient to establish an L70/B50 rating. L70 describes a lumen-maintenance threshold, while B50 identifies a population percentile under defined test conditions; neither is interchangeable with an unspecified service-life entry. Maintenance planning should use the applicable backlight specification and documented operating conditions.

    Ambient-light assessment should use the complete front assembly. An anti-glare surface can change reflections and perceived sharpness, so compare displayed text, dark fields, and critical symbols under representative illumination. No sunlight contrast guarantee follows from the panel’s typical contrast ratio. Sharp Devices Europe Industrial Display Solutions offers manufacturer context for display technology and application assessment.

    Industrial Bezel Mechanical Envelope Tolerances & Mounting Screw Torque Optimization

    Check support-pad contact and bezel flatness before tightening the retaining hardware around the 2.4 mm panel depth. The outline dimensions establish the module envelope, while the 317.117 × 211.411 mm active area defines the visible image region. Neither dimension establishes a permissible clamping load or a screw location.

    As an Engineering Recommendation, distribute retention forces through the intended support features and assess gasket compression around the perimeter. Uneven compression can stress the assembly and contribute to pressure-related luminance variation or mura. Compare a uniform dark image before and after fastening; a change with mechanical loading warrants checking the support arrangement rather than immediately adjusting image electronics.

    Fastener torque depends on the enclosure joint, thread engagement, and approved mounting scheme. A generic M3 torque range should not become a panel installation requirement. Dust sealing should also preserve thermal movement and cable clearance rather than relying on excessive bezel pressure.

    Maintenance Note: Periodically inspect ventilation passages and bezel gaskets for blockage, displacement, or compression loss.

    During replacement assessment, compare LQ150X1DW11 separately against the original mechanical drawing and host interface requirements. A similar model designation or screen-size class does not establish interchangeability; resolution, connector assignment, electrical requirements, and mounting geometry determine whether further evaluation is appropriate.

    Four-Lane eDP Interface and Panel Power Verification

    Match the host output to the four-lane eDP, 60-pin interface before connecting the LQ150P1JX01. This panel uses eDP, so parallel TTL RGB timing and LVDS JEIDA/VESA mapping are not its native connection scheme. A connector’s pin count alone does not establish pin compatibility.

    As a Design Consideration, maintain differential-path continuity through the cable, connector, and host routing. Impedance discontinuities, pair imbalance, and excessive channel loss can reduce link margin; evaluate the complete path against the applicable eDP channel requirements. Supply behavior and backlight control should follow the approved pin assignment and sequencing, with measurements taken at the panel connector.

    For grayscale errors or split-screen artifacts, compare native-resolution test patterns, host timing, and link behavior before attributing the symptom to the timing controller. Gamma adjustments should follow stable image transmission; they cannot repair a disturbed digital link.

    When evaluating a high-voltage substation protection terminal or SCADA dispatch console, designers should verify controller support, front-window readability, and enclosure conditions against the installation requirements. Record connector-level supply behavior and image stability through startup and shutdown to assess compatibility with the complete console.

    More Related Parts